Customization: | Available |
---|---|
Energy Efficiency Grade: | Two |
Heat Temperature: | 50-70°C |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Water Cooled Screw Chiller Recirculating Chiller Industrial Cement Cooling
|
||||||
Model
|
TC-90W
|
TC-125W
|
TC-180W
|
TC-240W
|
TC-300W
|
|
Cooling Capacity
|
Kw
|
92
|
126
|
177
|
236
|
295
|
USRT / Ton
|
26.2
|
35.8
|
50.3
|
67.1
|
83.9
|
|
Kcal/h
|
79120
|
108360
|
152220
|
202960
|
253700
|
|
Power Supply
|
3PH-380V-50Hz or according to customer local need
|
|||||
|
Type
|
R22 / R407c / R134a /R507
|
||||
Control
|
Thermostatic expansion valve
|
|||||
|
Type
|
Semi-hermetic screw type
|
||||
Power (Kw)
|
23
|
32
|
42
|
57.5
|
70
|
|
Start Type
|
Y-△
|
|||||
Capacity Control
|
25-50-75-100(%)
|
|||||
|
Type
|
Shell and tube
|
||||
Water flow ( m3/h)
|
15.8
|
21.6
|
30.3
|
40.5
|
50.3
|
|
Inlet / Outlet
|
DN100
|
DN65
|
DN80
|
DN80
|
DN100
|
|
|
Type
|
Shell and tube
|
||||
Cooling flow (m3/h)
|
21.7
|
29.8
|
41.3
|
55.3
|
68.8
|
|
Inlet / Outlet
|
DN50
|
DN65
|
DN80
|
DN80
|
DN100
|
|
Protect System
|
Compressor overheat protection, high/low pressure protection, phase missing/sequence protection, flow rate protection, anti-frozen
protection. |
|||||
|
L(mm)
|
2300
|
2500
|
2500
|
2800
|
3200
|
W(mm)
|
750
|
750
|
750
|
800
|
800
|
|
H(mm)
|
1500
|
1500
|
1500
|
1500
|
1500
|
|
Weight
|
KG
|
660
|
700
|
975
|
1150
|
2000
|
Water Cooled Screw Chiller Recirculating Chiller Industrial Cement Cooling
|
||||||
Model
|
TC-350W
|
TC-500W
|
TC-600W
|
TC-650W
|
TC-750W
|
|
Cooling Capacity
|
Kw
|
352
|
480
|
611
|
634
|
740
|
USRT / Ton
|
100
|
136.5
|
173.7
|
180
|
210
|
|
Kcal/h
|
302720
|
412800
|
525460
|
545240
|
636400
|
|
Power Supply
|
3PH-380V-50Hz or according to customer local need
|
|||||
|
Type
|
R22 / R407c / R134a /R507
|
||||
Control
|
Thermostatic expansion valve
|
|||||
|
Type
|
Semi-hermetic screw type
|
||||
Power (Kw)
|
78
|
106
|
134
|
142
|
165
|
|
Start Type
|
Y-△
|
|||||
Capacity Control
|
25-50-75-100(%)
|
|||||
|
Type
|
Shell and tube
|
||||
Water flow ( m3/h)
|
60.3
|
82.3
|
104.7
|
108.7
|
126.9
|
|
Inlet / Outlet
|
DN100
|
DN100
|
DN100
|
DN125
|
DN125
|
|
|
Type
|
Shell and tube
|
||||
Cooling flow (m3/h)
|
81.1
|
110.5
|
140.5
|
146.3
|
170.7
|
|
Inlet / Outlet
|
DN100
|
DN100
|
DN100
|
DN125
|
DN125
|
|
Protect System
|
Compressor overheat protection, high/low pressure protection, phase missing/sequence protection, flow rate protection, anti-frozen
protection. |
|||||
|
L(mm)
|
3500
|
3500
|
3500
|
3800
|
3800
|
W(mm)
|
900
|
900
|
900
|
900
|
1200
|
|
H(mm)
|
1500
|
1500
|
1800
|
1800
|
1800
|
|
Weight
|
KG
|
1600
|
1600
|
1750
|
1850
|
2000
|